Efficient tool for museum lighting design,
More flexible, more excellent
Tracron M5 track lights provide museum quality light, unparalleled lighting effect and intelligent lighting control, flexibly and conveniently cooperate with different lighting designs.
Quick to read the specifications and light distribution data sheet
Sunlight condition
Illuminance (lx)
Direct sunlight on ground in summer
7000-110000
Outdoor ground in sunny day (no direct sunlight)
5000-24000
Interior ground with good daylighting
100-1000
Arttificial lighting on working desktop
100-500
Outdoor ground in full moon night
0.5
What is illuminance?
When the lighting lights upon an object, we say surface of this object is being illuminated. The lighting level of the surface is measured by illuminance, and the illuminance is the amount of luminous flux per unit area (total luminous flux incident on a surface divided the acreage of the surface).
The origin of light distribution angle
The light distribution curve has a half-light intensity angle of 26° and belongs to a rotationally symmetric light distribution.
(The half-light intensity angle is the half-value angle, which is the normal direction of the center of the light source, and the angle of 50% of the maximum cd value.)
The maximum intensity value of the luminaire *0.5 and the intersection of the light curve is the angle of the obtained light type.
(The half-light intensity angle is the half-value angle, which is the normal direction of the center of the light source, and the angle of 50% of the maximum cd value.)
The maximum intensity value of the luminaire *0.5 and the intersection of the light curve is the angle of the obtained light type.
Maximum Light Intensity
Maximum Light Intensity*0.5
Lighting distribution data
Luminous intensity
Light intensity contour
Angle contour
Illumination map
H(m)
H: vertical illumination height
Vertical distance from the light exit of the luminaire to the illuminated surface
Vertical distance from the light exit of the luminaire to the illuminated surface
D(m)
0.21/0.0.41/0.62/0.83/1.03
The diameter of the light type corresponding to the irradiation distance H
The diameter of the light type corresponding to the irradiation distance H
H(m)
E is the maximum illuminance value of the center when the irradiation distance is H
Oval light type curve
Luminous intensity
Light intensity contour
Angle contour
Illumination map
H(m)
H: vertical illumination height
Vertical distance from the light exit of the luminaire to the illuminated surface
Vertical distance from the light exit of the luminaire to the illuminated surface
D(m)
C0
C0
0.21/0.0.41/0.62/0.83/1.030.98/1.95/2.93/3.90/4.88 Diameter of the light type corresponding to the irradiation distance H
D(m)
C90
C90
0.43/0.85/1.28/1.70/2.13
Diameter when C90 direction is the short axis direction and the irradiation distance is H
Diameter when C90 direction is the short axis direction and the irradiation distance is H
E(lx)
E is the maximum illuminance value of the center when the irradiation distance is H
Wallwash light type curve
Wallwash is asymmetrical lighting pattern, continuously splicing multiple wallwash can offer great uniformity for a space from the top ceiling to the bottom with impressive spacious atmosphere; Wallwash is particular suitable for large flat exhibits and anaglyph artworks.
Light intensity contour
Angle contour
Tracron M5 tracklights beam angle guidelines
Height Distance from the wall
Recommended wattage and beam angle
5m
2000mm
4m
1600mm
3m
1200mm
1.6m
20W: 15°,26°,47°,54°x24°,Wallwash
12W: 6°,9°
12W: 6°,9°
20W: 15°,26°,47°,54°x24°,Wallwash
12W: 6°,9°
12W: 6°,9°
14W: 15°,26°,54°x24°,Wallwash
12W: 6°,9°
12W: 6°,9°
Note: All above data is provided only for your reference. Lighting performance might be different according to various exhibition space layouts. Please call 400-687-2598 for specific lighting guide.
Tracron M5 tracklights lighting guidelines
Beam angle
AKZU concentrates on professional museum lighting, provides full range of beam angles and light types, meets the practical appliction of lighting environment, pursuits for perfect presentation of precious exhibits.
Installation guide video
Tracron M5 tracklights installation guidelines
Benefiting from AKZU's flexible and convenient track lighting system, Tracron track lighting fixtures have various installation modes: pendant mounting, ceiling mounting, recessed mounting, horizontal mounting on wall, vertical mounting on wall, etc.
Pendant mounting
When the space is high, the structure of the ceiling is irregular or there is no ceiling, pendant mounting is the best choice. Tracks can be installed at suitable height by pendant cable or pendant rod.
Ceiling mounting
Ceiling mounting is one of the most convenient and quick installation mode, when the space height is suitable and a flat ceiling is available, or there is suitable crossbeam structure on the ceiling.
Recessed mounting
When the space height is suitable, recessed mounting can be applied to get the tracks well-hidden into the ceiling, obtaining the most high grade, clean and comfortable integral effect.
Single ceiling mounting
For no-ceiling and track mounting unavailable space, or exhibits positioned quite far away even in arc route, single ceiling mounting would be the best choice.
Single recessed mounting
For ceiled limited-height space or independent space, single recessed mounting ensures luminaire installed closely on ceiling, avoid repression under low space height, and simplify lighting space.
Tracron M5 light types application
Direct spot: 6° and below
Direct spot 6° provides strong brightness contrast to the exhibits and environment, generates great visual impact. It can be used in high roof space with great highlighting effect.
Narrow spot: 7°-10°
Narrow spot 9°, precise lighting and extreme uniformity, is available to use in high ceiling and attach visitors' full attention to exhibits.
Spot: 11°-25°
Spot 15° with strong brightness focuses on exhibit, gives enough contrast as the environment and let the exhibit stands out.
Flood: 25°-45°
Flood 26° creates a medium-size, soft and bright lighting pattern, indicating the true texture of the exhibit. It is particular suitable for medium-size paintings and three-dimensional works.
Broad flood: 45°-60°
Broad flood 47° with pure and soft lighting can perfectly presents the details of the exhibit to visitors; It is suitable for large flat exhibits and also good to use as background lighting of three-dimensional exhibits.
Oval flood (Horizontal)
Oval flood 54°x24° generates a horizontal elliptical pattern, soft long lighting, it is ideal use for long strip paintings.
Oval flood (Vertical)
Oval flood 24°x54° provide s a vertical elliptical pattern lighting. It is perfect for calligraphy and painting artworks.
Wallwash
Continuously splicing multiple wallwash can offer great uniformity lighting for a space from the top ceiling to the bottom with impressive spacious atmosphere; Wallwash is particular suitable for large flat exhibits and anaglyph artworks.
Tracron M5 Museum lighting projects
Sichuan Museum
Founded in 1941, Sichuan Museum has a main building area of 32,026 square meters. It currently has 14 exhibition halls with a total area of 12,000 square meters. There are more than 320,000 pieces of cultural relics in the museum, including more than 50,000 precious cultural relics. The Sichuan Museum is not only a national first-class museum, but also the largest comprehensive museum in the Southwest.
The Palace Museum (Shenwumen showroom)
Established in 1925, The Palace Museum is a large-scale comprehensive national first-class museum based on the Imperial Palace of the Ming and Qing Dynasties (the Forbidden City) and the old palace cultural relics. The total number of existing collections has reached more than 1.8 million sets, including more than 8,000 pieces of first-class collections.
Yinchuan Contemporary Art Museum
In August 2015, Yinchuan Contemporary Art Museum was officially opened. The museum covers an area of about 35 mu and has a construction area of 15,000 square meters. The environment is beautiful and surrounded by wetland parks.
China (Hainan) Museum of the South China Sea
In April 2018, China (Hainan) Museum of the South China Sea, which faces the South China sea, was officially opened. Its total construction area is 70,593 square meters.
Shanxi Museum
In 2004, the new building was completed and officially named Shanxi Museum. It is national first-class museum, also it is the museum with largest scale investment in Shanxi province after People's Republic of China established.
Shenzhen Nanshan Museum
After 4 years of preparation and construction, Shenzhen Nanshan Museum was officially opened in January 2018. With land area of about 19,000 square meters, construction area of about 36,000 square meter, and 4,000 pieces of collections, it is one of the largest museums in construction area among district and county grade cities.